GT20 IV Self-Test TR
GT20 IV Self-Test TR
GT20 IV Self-Test TR

GFCI Receptacle,Self-Test GFCI,GT20 IV

Description
Specifications

Features and Benefits

  • Self-Test
    ■ GFCI shall automatically conduct self-test every 15 minutes to ensure continuous protection.

    ■ Auto-monitoring exceeds the UL requirement UL943 2018 version.

    ■ On initial power up, tests the GFCI within 3 seconds.

    ■ Enhanced Service Life led indicator lamp integrates two-color function: Green/Red.

    ■ Strong anti-interference design.

    ■ Enhanced Service Life led indicator lamp integrates two-color function: Green/Red.

General Features

  • 1.Trip threshold meets or exceeds UL requirements for tripping time.

    2.UL Standard 943 Class A & UL498 for Receptacle.

    3.Advanced electronics design provides superior resistance to electrical surges and over-voltages.

    4.Standard copper parts are integrated stamping one-piece design to ensure stable work.

    5.TEST and RESET button colors match device face (Red & blue buttons optional).

    6.Standard thickness silver contacts ensure good contact.

    7.Three colors led indicator light provides simple, intuitive feedback on power and protection status.

    8.If the GFCI installed in correct wiring, the automatic detection function detects once within 3 seconds once power-on, and the red indicator flashes once in each internal detection cycle. Green led indicator will on once GFCI been reset, and the receptacle get power.

    9.Please replace the GFCI if the red led indicator on and can not reset.

    10.Side or internal screw-pressure-plate back wire with #10-#14 AWG solid or stranded copper wire.

    11.Auto-Ground clip assures a positive ground to metal box.

Line-load reversed Protection

  • If line/load reversed, the Green led indicator will on before GFCI been Reset, no power will be delivered to receptacle face.

Tamper-Resistant GFCI (TR)

  • The receptacle blocks access to the contacts unless a two- or three-prong plug is inserted.

    Complies with NEC® requirement mandating that all 15A and 20A receptacles installed in dwelling units be listed as tamper-resistant. Following items with tamper-resistant shutter mechanism inside:

    GT15/GT20
    GW15/GW20
    GTN15/GTN20

Item: GT20

Electrical Specifications


Dielectric Voltage

Withstands 1250VAC per UL 943

Self Testing

Yes

Amperage

20 Amp

Voltage

125 VAC

Power Frequency

60 Hz

Pole

2

Wire

3

Grounding

Self Grounding With Grounding Clip

Short Circuit Current Rating

10KA

Trip Level

Class A, 6mA plus or minus 4mA

Trip Time

<25ms

Material Specifications


Body Material

PC-Thermoplastic Flammability UL-94 V2 Rating

Face Material

PC-Thermoplastic Flammability UL-94 V2 Rating

Terminal Screws

Plated Steel

Grounding Screw

Plated Steel

Clamps

Brass

Line Contacts

Brass

Yoke

Zinc-Plated Steel

Shutter Mechanism

Thermoplastic & Acetal

Mechanical Specifications


Terminal ID

Brass-Hot, Green-Ground, Silver-Neutral

Terminal Accom

14-12 AWG

Product ID

Ratings Are Permanently Marked On Device

Tamper Resistant

Yes

Termination

Back & Side

Environmental Specifications

Operating Temperature: -35℃ to +66℃

Standards and Certifications


NEMA

5-20R

Applicable Standards

UL/CUL UL498/UL943 5th Edition

Warranty

2-Years Limited

Grade

Residential/Commercial Specification Grade

Product Catalog