GW20 WH Self-Test TR/WR
GW20 WH Self-Test TR/WR
GW20 WH Self-Test TR/WR

20Amp 125V AC 60Hz GFCI Outlet, Self-Test UL/Cul Listed E504391 White Color, Tamper Resistant & Weather Resistant, Standard/Screwless Wallplate Optional, UL943 5th Edition /UL498 /UL1998

Description
Specifications

Features and Benefits

  • Self-Test
    ■ GFCI shall automatically conduct self-test every 15 minutes to ensure continuous protection.

    ■ Auto-monitoring exceeds the UL requirement UL943 2018 version.

    ■ On initial power up, tests the GFCI within 3 seconds.

    ■ Enhanced Service Life led indicator lamp integrates two-color function: Green/Red.

    ■ Strong anti-interference design.

    ■ Enhanced Service Life led indicator lamp integrates two-color function: Green/Red.

General Features

  • 1.Trip threshold meets or exceeds UL requirements for tripping time.

    2.UL Standard 943 Class A & UL498 for Receptacle.

    3.Advanced electronics design provides superior resistance to electrical surges and over-voltages.

    4.Standard copper parts are integrated stamping one-piece design to ensure stable work.

    5.TEST and RESET button colors match device face (Red & blue buttons optional).

    6.Standard thickness silver contacts ensure good contact.

    7.Three colors led indicator light provides simple, intuitive feedback on power and protection status.

    8.If the GFCI installed in correct wiring, the automatic detection function detects once within 3 seconds once power-on, and the red indicator flashes once in each internal detection cycle. Green led indicator will on once GFCI been reset, and the receptacle get power.

    9.Please replace the GFCI if the red led indicator on and can not reset.

    10.Side or internal screw-pressure-plate back wire with #10-#14 AWG solid or stranded copper wire.

    11.Auto-Ground clip assures a positive ground to metal box.

Line-load reversed Protection

  • If line/load reversed, the Green led indicator will on before GFCI been Reset, no power will be delivered to receptacle face.

Tamper-Resistant GFCI (TR)

  • The receptacle blocks access to the contacts unless a two- or three-prong plug is inserted.

    Complies with NEC® requirement mandating that all 15A and 20A receptacles installed in dwelling units be listed as tamper-resistant. Following items with tamper-resistant shutter mechanism inside:

    GT15/GT20
    GW15/GW20
    GTN15/GTN20

Weather-Resistant GFCI (WR)

  • UV stabilized plastics

    Designed for wet and damp locations which meet the requirements of NEC Section 406.8 Tamper-Resistant shutter mechanism inside.

    Please use waterproof box when GFCI installed nearby water being directly polluted.

    GW15/GW20

Product Catalog